  ALL

B

Blast Controller

A person who may be appointed to handle the logistics of the clearance of the Blast Exclusion Zone including (but not limited to) the following:-

  • Removal / relocation and preparation of equipment currently within the Blast Exclusion Zone;
  • Confirming the position and location of the Blast guards;
  • Completing the clearance sweeps of the Blast Exclusion.

Zone once the guards are in place and the area secured.

Blast Guard

A blast guard is a person responsible for ensuring the blast clearance zone is evacuated prior to the firing of a blast.

The attached document provides detailed information on the practice of blast guarding.

blast guard cover

Blast Mat

A mat made of rope, rubber strips, polyethylene tube or similar material, placed over the area or materials being blasted to prevent the scattering of blast-generated debris.

blastmat

Blast Plan

A blast plan, should include, but not be limited to, the following:

  • Location of the proposed blasting.
  • Description of the proposed blasting.
  • Permits / licences required for the project.
  • Identification and position of the person responsible for the project including project safety and security.
  • Identification and position of person who has given approval to use explosives on the project.
  • Key appointments and responsibilities.
  • Shotfirer’s details.
  • Details of the risk management assessment.
  • Details of adjacent structures or services that influence the blast design.
  • Details of reports, drawings and records consulted.
  • Layout plan of the blast including drilling pattern and hole depths.
  • Detonation sequence / effective charge mass per delay (MIC) / powder factor.
  • Type of explosive to be used and quantity required.
  • Method of initiation.
  • Type of firing equipment and procedures.
  • Drilling procedures.
  • Explosive loading and charging procedures.
  • Explosive storage and handling procedures.
  • Security procedures for the site and the blast, including explosives.
  • Environmental considerations for airblast overpressure, ground vibration.
  • Details of communication systems.
  • Warning procedures.
  • Traffic management plan.
  • Proposed dates and times of blasting.
  • Details of the exclusion zone.
  • Method of notification to owners and occupiers of structures, and providers of services adjacent to the blast.
  • Influence of weather.
  • Loading in poor light conditions or reduced visibility.
  • Cessation of explosive-related activities during electrical storms.
  • Misfire management system.
  • Post blast assessment and inspection procedures.
  • Provision for post-blast comments.
  • Signature spaces for the plan author, shotfirer and person who approves the plan.

Blast Report

The blast report is the record of blast firing.

Details of the blast should be taken and maintained, including but not limited to the following:

  • Drill pattern, product loaded (type and quantity) initiation sequence.
  • Environmental conditions at the time of the blast.
  • Monitoring equipment including type, serial number and location.
  • Details of measurements recorded during the blast.
  • Details of flyrock or fly.
  • Details of incidents and complaints.
  • Comment on the results of the blast.
  • Proposed modification to the blast plan for future shots.

Blast Site

An area including all holes to be loaded plus such as required for safe loading operations.

Blasting Agent

Certain high explosives, such as those consisting primarily of ammonium nitrate, in which none
of the ingredients are classified as an explosive and which normally require a booster for initiation.

Blasting Ohm-meter

A Blasting Ohm Meter is a test device for checking circuits containing electric detonators.

A blasting ohm meter has an output limited to below the no fire current of standard electric detonators.

stinger testerreotester

BlastPED

BlastPED has been developed as a safer alternative to traditional safety fuse and cable based firing systems. This radio based remote blasting system allows personnel to be away from the blast area, reduces the number of misfires, and eliminates the need for expensive blasting cabling networks.

  • The BlastPED System operates off the existing PED Transmission System and only requires a software upgrade to operate.
  • BlastPED has been developed to eliminate the high cost of maintaining the integrity of underground blasting cables. By eliminating these cables, costs are reduced on maintenance and lost production due to misfires.
  • While the BlastPED system is extremely secure, it is also simple to operate for the authorised personnel. The software is similar to the PED operating software, PEDCALL; therefore personnel do not need to learn a new system.
  • The actual BlastPED receiver itself is easy to connect and operate. The user connects the firing cable, ensures the BlastPED has synchronised, and then turns the key. It is then up to the PEDCALL operator to enter the ARM & BLAST command from security disk and transmit the messages, once the area has been cleared of personnel and permission has been received to fire.
  • For safety reasons, two seconds after firing the BlastPED automatically locks out. The unit will remain locked until it is manually reset by turning the safety key to the “SAFE” position.

blastped

BlastPLAN-PRO

BLASTPLAN-PRO is a graphically based initiation design and simulation package for Shotfirers and Drill and Blast Engineers.

A free, fully functional system is available for download at www.blastplan.com.au

 blastplan pro


Page: (Previous)   1  2  3  4  5  6  7  8  9  10  ...  38  (Next)